WARNING 
A small amount of coolant can leak when servicing the coolant filter with the shutoff valve in the OFF position. To reduce the possibility of personal injury, avoid contact with hot coolant.

 WARNING 
Coolant is toxic. Keep away from children and pets. If not reused, dispose of in accordance with local environmental regulations.

 WARNING 
All diesel engines with wet liners are subject to liner pitting if the cooling system is not correctly maintained. Underconcentration (below 0.3 units per liter [1.2 units per gal] of Extended Service Additive/SCA results in liner cavitation and possible engine failure. Overconcentration (above 1.3 units per liter [5.0 units per gal] of additives) or the use of high-silicate antifreeze can result in silicate gelation or water pump seal leakage.

 WARNING 
When using chemical products for cleaning, follow the manufacturer\'s recommendations for use and disposal. Wear goggles and protective clothing to avoid personal injury.

 WARNING 
Some solvents are flammable and toxic. Read the manufacturer\'s instructions before using.

 CAUTION 
Extenders used in extended service interval systems are not fully formulated and must not be used in treated water coolants. Their usage can result in engine damage. See Section 8.

 CAUTION 
The recommendations in this section can in no way be interpreted as an endorsement by Cummins Inc. to use treated water in place of antifreeze/coolant.

 CAUTION 
Engines using cooled exhaust gas recirculation (EGR) must not use treated water coolant. The use of coolant with 40 to 60 percent antifreeze is mandatory on these engines. This is due to increased coolant temperatures.

 CAUTION 
Marine engines must use a minimum of 25 percent antifreeze/coolant for both initial fill and topping off, and must maintain high SCA levels as described below. Treated water coolants with less than 25 percent antifreeze must never be used in marine engines.

 CAUTION 
Failure to purge cleaning chemicals sufficiently can result in contamination of the new coolant during the refill process, which can lead to engine failure.

 CAUTION 
Coolants and cooling system cleaning and flushing fluids that contain 5 ppm or more of lead or 0.5 ppm of benzene are considered hazardous according to federal law in the United States of America. Disposal must be done in accordance with local, state, and federal laws.

 CAUTION 
The use of products containing hydrochloric acid will not result in adequate system cleanup and may attack cooling system materials.

 CAUTION 
Prolonged use of any cleaner, greater than 3 hours, is not recommended.

 CAUTION 
Do not use liquid dish soap. Foaming and air lock in the cylinder head(s) can occur causing severe engine damage.

 CAUTION 
Failure to maintain Extender/SCA concentration level can result in severe engine damage.


Service Bulletin Number Date
3666132-04  07-DEC-2005 
Design Application Market Application
All  All 

 Service Bulletin

Cummins® Coolant Requirements and Maintenance

This Service Bulletin supersedes prior Service Bulletins concerning Cummins Inc. coolant requirements and maintenance; replace those Service Bulletins with this one.

This Service Bulletin outlines the proper application and maintenance of coolant for all Cummins® engines, including gaseous fueled engines. It also updates and simplifies Cummins Inc. recommendations and guidelines for the end user.

Summary of Recommendations

Cummins Inc. cooling system general recommendations are listed below. These recommendations apply to both Standard Service Intervals and Extended Service Intervals. See Section 2 or 3 for complete instructions.

Definition of Terms

Term Definition
Extender Extended Service Additive
Coolant As used in this bulletin, coolant refers to the liquid mixture in the engine or vehicle cooling system that functions to maintain an engine temperature in the designed range. In general, the coolant is made up of water, glycol and additives. Also referred to as “Prediluted” or “Premix”.
Antifreeze The glycol and additive portion of the coolant whose main function is to control corrosion and the freezing/boiling point of the coolant. Also referred to as “Concentrate”.
Fully Formulated Antifreeze or coolant that contains the correct amount of additives to be used in a heavy duty engine. Fully formulated antifreeze/coolant meets D6210.
Partially Formulated Antifreeze or coolant that requires a “precharge” of supplemental coolant additive to protect against liner pitting and hot surface scaling. Partially formulated antifreeze/coolant does not meet D6210.
Treated Water Coolant Water containing all additives necessary for use as a coolant in heavy duty engines. Treated water coolant does not contain glycol.
Unit 0.3 units per liter [1 unit per gal] is equal to 1000 ppm of Nitrite (as NO 2).

Section 1 - Introduction

Cummins Inc. Coolant Recommendations

Cummins Inc. coolant recommendations have evolved over time to reflect changes in diesel engine and coolant technology, environmental regulations, and customer needs.

Since 1995, Cummins Inc. has recommended the use of only fully formulated coolants meeting ASTM D6210/The Maintenance Council RP 329 (ethylene glycol) and The Maintenance Council RP 330 (propylene glycol) specifications.

However, Cummins Inc. has recently discovered significant weaknesses in some coolants meeting these ASTM specifications. Therefore, a new Cummins Engineering Standard, Cummins Engineering Standard 14603, has been developed to make sure coolant used in Cummins® engines will meet the requirements of all engine components. See Attachment 2 for more information on Cummins Engineering Standard 14603.

Cummins Inc. guidelines prior to 1995 permitted the use of fully formulated antifreezes/coolants meeting ASTM D6210, but primarily addressed the use of partially formulated products meeting ASTM D4985 or GM 6038M, which were referred to as "heavy duty" based on the low-silicate content. These partially formulated coolants contained buffering compounds and corrosion inhibitors, but did not provide liner pitting and scale protection. To provide total heavy-duty cooling system protection, a mixing process was required to add SCA. This mixing process provided opportunity for human error, which often resulted in liner or block pitting from under-concentration during initial fill or SCA dilution during top-off of the cooling system. Because of these issues, the use of partially formulated antifreezes is unacceptable.

Fully formulated antifreezes are ideally suited for topping off cooling systems, but do not eliminate the need for additive replenishment. Routine additive replenishment has always been required to offset normal additive depletion processes.

During normal additive replenishment, it is possible to achieve an additive concentration that is higher than desired. This is because Cummins®-recommended replenishment rates have been aimed to compensate for coolant loss. If no coolant loss is experienced, gradual Extender/SCA concentration increase is possible. Overconcentration can be avoided by monitoring with a test kit.

However, the use of test kits to maintain a concentration near the minimum side of the acceptable range has never been acceptable nor recommended. This practice is responsible for many pitting failures and should not be followed.

Coolant Performance Characteristics

Table 1 below lists the various types of coolants and the performance characteristics of each. As mentioned earlier in this section, only fully formulated antifreeze/coolant meeting Cummins Engineering Standard 14603 is recommended for use in Cummins® engines.

Table 1 - Coolant Type versus Performance Characteristics

  Light Duty Heavy Duty/Low Silicate Low Silicate and SCA Fully Formulated
ASTM Specification D-3306 D-4985 D-6210
Buffering Yes Yes Yes Yes
Corrosion Protection Yes Yes Yes Yes
Foam Control Yes Yes Yes Yes
Silicate Limit No Yes Yes Yes
Liner-Pitting Protection No No Yes Yes
Scale/Deposit Control No No Yes Yes
SCA Precharge Required Yes No No
Silicate Gelation Primary cause Limits problem Can occur with SCA overdose No
Total Dissolved Solids Buildup in Coolant Can exceed 5 percent Remains below 3 percent
Extended Service Interval Capable No No No Yes
System Top-Off SCA added with antifreeze/coolant SCA added with antifreeze/coolant SCA added with antifreeze/coolant Antifreeze/Coolant only

Topping Off and Dilution of Cooling Systems

Coolant loss can lead to dilution of corrosion and liner-pitting protection additives due to incorrect top-off practices. This is the root cause of most cases of liner-pitting. The top-off process is simplified by the use of fully formulated antifreezes and coolants because SCA addition is not required when topping off the system. Even small leaks at the hose clamps, radiator cores, cylinder head gaskets, and water pumps result in significant coolant loss over time. Dilution of critical additives is avoided, regardless of the amount of coolant loss, by using fully formulated products for system top-off.

Standard Service Interval Coolant versus Extended Service Interval Coolant

Both types of coolant follow the same general test schedule:

The advantage to using an extended service interval coolant is that typically the coolant only needs additive replenishment and filter change once per year, compared to the standard service interval where the additive and filter is replenished at each oil change interval.

Section 2 of this bulletin details the standard service interval and Section 3 details the extended service interval.

Additional Information

If you have any questions about information in this bulletin or would like more information, please contact 1-800-DIESELS.

Section 2 - Standard Service Interval

This section outlines the recommended maintenance practices for cooling systems when using a standard service interval.

 WARNING 

A small amount of coolant can leak when servicing the coolant filter with the shutoff valve in the OFF position. To reduce the possibility of personal injury, avoid contact with hot coolant.

 WARNING 

Coolant is toxic. Keep away from children and pets. If not reused, dispose of in accordance with local environmental regulations.

For an engine using standard service interval coolant, the additive and glycol levels must be tested once every 6 months.

The following steps are required to comply with Cummins Inc. recommendations for initial filling and maintenance of cooling systems.

SCA Levels

Test the SCA level a minimum of twice a year.

Section 3 - Extended Service Interval

This section covers the requirements for coolant products that provide extended service maintenance intervals.

Extended service interval coolant is defined as a coolant capable of a minimum general routine service interval of 240,000 km [150,000 mi], 4000 hours, or 1 year, whichever occurs first. It must be noted that organic acid technology (OAT) coolants are generally capable of extended service intervals ranging from 500,000 km to 1,000,000 km [300,000 mi to 600,000 mi] or 6000 hours to 7000 hours. Follow maintenance guidelines recommended by the coolant manufacturer.

Successful usage of extended service interval products will be possible only if a systematic approach to coolant maintenance is followed by the user. This means using the extended service interval system of coolant products for all coolant maintenance at the fleet shop as well as on the road. Use of the proper coolant is vital for successful extended service interval maintenance. If control of top-off can not be accomplished, do not consider extended service and use the standard service interval as described in Section 2. Coolant must meet the requirements stated in this section.

It is preferred and recommended for all Cummins® engines to top off only with fully formulated coolants which meet Cummins Engineering Standard 14603. See Attachment 2 for more information on Cummins Engineering Standard 14603. However, MidRange products, including any Cummins® engine displacing less than 10 liters [610 C.I.D.], may top off with fully formulated coolants meeting a minimum requirement of ASTM D6210.

Cummins Inc. recommends Fleetguard® Antifreeze Coolants including ES Compleat containing DCA4 Plus, Fleetcool EX containing DCA2 Plus, and ES Optimax Organic Acid Technology (OAT), which meet the requirements of Cummins Engineering Standard 14603.

Cummins® Engines That are Using Chevron Texaco or Shell Rotella Extended Life Coolant (TELC) Plus Silicates

OAT coolants, such as Chevron Texaco, Shell Rotella or their private label counterparts, which do not meet the elastomer compatibility section of Cummins Engineering Standard (CES) 14603, are acceptable for extended service interval use in Heavy-Duty and High Horsepower engines if the initial coolant fill requirements were met by the vehicles' original equipment manufacturer (OEM), (including the addition of silicates). See Cummins AEB 90.47 which can be accessed on http://www.gce.cummins.com. Additional information is included in the appendix, titled Frequently Asked Questions.

Heavy-Duty and High Horsepower engines requiring overhauls or repairs involving the replacement of the following components that are using OAT coolants not meeting CES 14603, must discard the original coolant and replace with new.

If the replacement coolant is Chevron Texaco, Shell Rotella or their private label counterparts, which do not meet the elastomer compatibility section of CES 14603, the coolant must be treated by adding 0.24 liter [8 oz] of liquid silicate fluid for every 45 liters [12 gal] of total coolant system volume. It is critical to not over treat the coolant with silicate fluid. If over-treatment is suspected, drain the cooling system and discard the filter. Clean the cooling system immediately. Symptoms of silicate over-treatment can be thickened coolant in the lower radiator tank, water pump seal leakage soon after silicate addition, reduced heater output and/or elevated engine temperatures. Use Fleetguard® Restore Cooling System Cleaner at the rate of 3.8 liters [1 gal] per 38 to 45 liters [10 to 12 gal] of water. Do not use Restore with normal engine coolant.

To obtain order forms or ask questions relative to ordering the silicate fluid:

Phone: 800-346-9041

Fax: 800-876-5317

Mail To:

Silicate Fluid Order Program
P.O. Box 27388
Houston, TX 77227-7388

Extended Service Maintenance

Table 2 - Liner Pitting Protection Additive Levels Required at Initial System Fill

Additive Premixed Antifreeze/Coolant (ppm) (See Note 1) Type of Coolant Additive
Minimum Nitrite (measured as NO 2) 2000 ppm DCA2
Minimum Levels of Nitrite (measured as NO 2) and Molybdate (measured as MoO 4) 1300 ppm (See Note 2) DCA4

Note 1: Concentrated antifreeze/coolant levels are double the premixed levels.

Note 2: A combination of nitrite (NO 2) and molybdate (MoO 4) can not contain less than 500 ppm of either additive.

Extender/Extended Service Additive Levels

Test the SCA level a minimum of twice a year.

Extender Requirements

 CAUTION 

Extenders used in extended service interval systems are not fully formulated and must not be used in treated water coolants. Their usage can result in engine damage. See Section 8.

The Extender replaces the additives in the coolant that are lost due to depletion. It can be added as a liquid directly to the coolant or as a solid contained in a coolant filter.

Cummins Inc. recommends using a Fleetguard® ES™ slow release filter or ES™ Extender liquid.

Performance Requirements

The Extender must contain sufficient liner-pitting additives to increase the levels of nitrite or nitrite plus molybdate in the engine coolant by the following amounts:

A combination of nitrite and molybdate can not contain less than 200 ppm of either additive.

Storage Stability

Liquid Extenders typically have a shelf life of at least 2 years from the time of manufacture when stored at temperatures ranging from -7° to 55°C [19° to 131°F].

Solid material, liquid turbidity, or layering at the top of the liquid is allowed if it will dissolve and disperse by stirring the solution and warming it to a temperature between 2° to 67°C [36° to 153°F].

Solid, slurry, and paste forms of Extender must dissolve completely in hot engine coolant. They must be formulated and packaged to prevent chemical or physical change during storage temperatures ranging from -7° to 55°C [19° to 131°F] regardless of humidity.

Section 4 - Unacceptable Maintenance Practices for Cooling Systems

 WARNING 

All diesel engines with wet liners are subject to liner pitting if the cooling system is not correctly maintained. Underconcentration (below 0.3 units per liter [1.2 units per gal] of Extended Service Additive/SCA results in liner cavitation and possible engine failure. Overconcentration (above 1.3 units per liter [5.0 units per gal] of additives) or the use of high-silicate antifreeze can result in silicate gelation or water pump seal leakage.

Unacceptable Practices - The following practices are considered unacceptable and may lead to engine failure.

Section 5 - Recommended Maintenance Practices for Cooling Systems of A and B Series Engines

The A and B Series engines normally do not require Extender/SCA because they do not normally experience cylinder bore/liner cavitation corrosion. Also, the A and B Series engines do not have an integral coolant filter.

Coolant maintenance requirements for the Cummins B series engines depend on the application.

Light duty applications can use coolant meeting ASTM D4985 and follow the maintenance schedule in the appropriate Owners manual. However, if ASTM D4985 antifreeze is used, it must additionally meet the elastomer capability section of Cummins Engineering Standard 14603.

A coolant filter must be installed on the B Series engines when used in higher utilization/commercial applications. The general recommendations in Section 2 or Section 3 must also be followed. Fleetguard offers the following parts to install a coolant filter on B series engines:

Standard Duty Filter Head - 204163S
Heavy Duty Filter Head - 3904378S
Mounting Bracket - 256535

Use of fully formulated antifreeze/coolant in this engine is acceptable but not required. If fully formulated antifreeze/coolant is used, it must meet a minimum requirement of ASTM D6210.

Section 6 - Coolant Testing

Coolant testing is required for two reasons:

  1. To determine the additive concentration and glycol level of the coolant. This will make sure that adequate liner pitting and freeze point protection are achieved.
  2. To determine if the coolant must be replaced due to contamination.

Coolant testing for additive and glycol levels must be performed at least twice a year. The coolant must also be tested for replacement limits every 240,000 km [150,000 mi], 4000 hours, or once a year, whichever occurs first.

Additive and glycol testing is also recommended when the following occur:

Coolant Replacement Limits

Table 3 below lists the limits for various coolant contaminants.

Table 3 - Coolant Replacement Limits

Contaminant Allowable Level
Sulfate (SO 4) 1500 ppm, maximum
Chloride (Cl) 200 ppm, maximum
Oil or fuel contamination Coolant must not contain oil or fuel
pH 6.5, minimum (See Note 1)
Grease, solder bloom, silica gel, rust, or scaling Coolant must be free of these contaminants

Note 1:The minimum pH for a replacement limit can vary according to the product. Consult the product manufacturer for the pH limit. A pH less than 6.5 is always unacceptable. For Fleetguard® ES™ Compleat™ coolant, the coolant must be replaced if the pH is below 7.5 pH.

If the coolant does not meet the replacement limits of sulfate, chloride, or pH, it must be drained and replaced with new coolant meeting Cummins Engineering Standard 14603. However, if the coolant is contaminated with oil, fuel, grease, solder bloom, silica gel, rust, or scaling, the system must be drained, cleaned and refilled. See Section 11 for details on cleaning the cooling system.

Coolant Testing Kits

Coolant testing and monitoring are useful tools for tracking and controlling coolant condition and performance. The methods available for testing coolants include field test kits, portable refractometers, and coolant analysis programs. Cummins Inc. recommends using the following Fleetguard® products:

Coolant Additive and Glycol level testing:

Part Number Quantity Foil Sealed
CC2602 50 No
CC2602A 4 Yes
CC2602B 100 Yes

Coolant testing for contamination/replacement limits:

Part Number Quantity Foil Sealed
CC2607B 100 Yes
CC2607C 25 Yes

Coolant freeze point testing

Coolant analysis program

The Three-Way™ heavy duty coolant field test kit is appropriate for testing nitrite-molybdate formulations, such as Fleetguard® DCA-4 as well as nitrite formulations such as Fleetguard® DCA2 (Fleetcool).

Fleetguard® Quik-Chek™ test strips will detect contamination levels that indicate replacement of the coolant is required.

The Monitor C™ program can evaluate most new or used coolant formulations.

Field test kits offer the benefit of on-site measurements and are designed to approximate Extender/SCA levels and freezing points. When required, freezing points can be more accurately determined with on-site refractometer readings.

When using the Fleetguard® Three-Way™ heavy duty coolant test kit, it is important to follow the instructions provided in the kit. Contact Fleetguard® Technical Assistance at 800-223-4583 or www.fleetguard.com for additional information.

Because the kit measures nitrite and molybdate separately, it can reliably measure both Fleetguard® SCA formulations as well as most competitive SCA formulations. Cummins Inc. recommendation for a nitrite-molybdate formulation for pitting protection is explained in Attachment 1 - Summary of Coolant Additive Technology.

Coolant analysis programs are performed in laboratories and offer additional, useful information but require mailing coolant samples to a laboratory. Laboratory measurements typically include the following:

Correct interpretation of laboratory data can provide additional guidance in coolant treatment effectiveness and early warning detection. Interpretation and further treatment action(s) are generally provided with laboratory results. Therefore, laboratory testing is typically very cost effective for the long term when used to optimize cooling system performance and life. However, it must not be used as a method for minimizing treatment.

See Attachment 3 for a sample Monitor C™ report.

Section 7 - Antifreeze

The primary purpose of antifreeze is to lower the freezing point of the coolant. Additional performance characteristics of coolants that are affected by the use of antifreeze include boiling point and vapor pressure. Antifreeze decreases vapor pressure, which is very beneficial to the reduction of cavitation corrosion liner pitting. This characteristic is the primary basis for Cummins Inc. requirement for increased SCA levels when antifreeze falls below 40 percent by volume.

A 50/50 mixture of antifreeze and water provides optimum boiling and freezing point protection for engines. An antifreeze concentration in excess of 60 percent must never be used, except in arctic climates, since it increases the possibility of forming cooling system gel, which results as silicates precipitate out of solution. However, an antifreeze concentration of less than 40 percent increases the possibility of coolant freezing and liner pitting. Therefore, Cummins Inc. recommends an antifreeze concentration range of 40 to 60 percent.

Fluids presently used in antifreeze are ethylene glycol and propylene glycol. Diesel engine antifreeze has primarily used ethylene glycol products because they are less expensive than propylene glycol products. However, some applications require less toxic coolant products and have driven the use of propylene glycol. The comparative properties are similar for ethylene glycol and propylene glycol and are listed below. Properties of pure water are shown for comparison.

Table 4 - Properties of Ethylene Glycol and Propylene Glycol Antifreeze versus Water

Property Ethylene Glycol (percent by volume) Propylene Glycol (percent by volume) Pure H 2O
Glycol Concentration 40 50 60 40 50 60 0
Specific Gravity, 16°C [60°F] 1.062 1.076 1.088 1.038 1.043 1.047 1.000
Freezing Point °C [°F] -24 [-12] -37 [-34] -52 [-62] -21 [-6] -33 [-27] -49 [-56] 0 [32]
Boiling Point °C [°F] at atmospheric pressure 106 [222] 108 [226] 111 [232] 104 [219] 106 [222] 109 [228] 100 [212]

Section 8 - Treated Water Coolant

 CAUTION 

The recommendations in this section can in no way be interpreted as an endorsement by Cummins Inc. to use treated water in place of antifreeze/coolant.

 CAUTION 

Engines using cooled exhaust gas recirculation (EGR) must not use treated water coolant. The use of coolant with 40 to 60 percent antifreeze is mandatory on these engines. This is due to increased coolant temperatures.

For purposes of this document, any coolant mixture with less than 40 percent antifreeze is considered to be “treated water” and requires increased supplemental coolant additives (SCA) as described in this section. Cummins Inc. does not recommend that water treated with additives be used in place of fully formulated antifreeze/coolant. However, it is recognized that certain applications operating only in warm-weather areas may have compelling reasons to use treated water coolants. This section gives some guidance on using treated water coolant in place of antifreeze/coolant if the user chooses to do so.

Customers must also be advised that not using fully formulated antifreeze at 40 to 60 percent glycol levels will reduce the level of engine protection against boil over, liner pitting, water pump cavitation, corrosion, scale and deposit formation, heater core freeze up, and microbial deterioration. Not using antifreeze can also decrease engine and vehicle cooling system component life.

NOTE: Minimum SCA level required for treated water coolant is 0.8 units per liter [3 units per gal] and not 0.3 units per liter [1.2 units per gal] as required in other sections of this bulletin.

Supplemental coolant additive (SCA) levels between 0.8 to 1.3 units per liter [3 to 5 units per gal] must be achieved and maintained through routine replenishment. Replenishment is necessary to make up for depleted SCA chemicals that are spent during normal operation. Incorrect concentration levels can be avoided by usage of the test kit described in Section 6. Cummins Inc. requires the use of quality water (see Section 9) and SCA meeting the ASTM D5752 specification, (see Attachment 2). The greater the water concentration, the more important its purity.

 CAUTION 

Marine engines must use a minimum of 25 percent antifreeze/coolant for both initial fill and topping off, and must maintain high SCA levels as described below. Treated water coolants with less than 25 percent antifreeze must never be used in marine engines.

The following steps are required for initial filling and maintenance of treated water cooling systems.

The recommended SCA is Fleetguard®'s liquid DCA4 containing molybdates as well as nitrites. In addition to providing the needed liner and block protection, the engine's tolerance of excess concentrations of DCA4 is higher as compared to DCA2. Fewer dissolved solids are used in the DCA4 chemical formulation, which reduces the tendency for water pump seal buildup and leakage. SCA formulations that do not contain molybdates, such as Fleetguard®'s liquid Fleetcool (DCA-2), can be successfully used if excess concentrations are avoided.

Section 9 - Water Quality Requirements

Cooling systems perform best with distilled or deionized water. If distilled or deionized water is not available, the quality of the water used must meet all the requirements listed below. Excessive levels of calcium and magnesium contribute to scaling problems, and excessive levels of chloride and sulfate cause cooling system corrosion. If water quality is unknown, it can be tested with the Fleetguard® Monitor C™ program or Water-Chek™ test strip. Water test results can also be obtained from local water utility departments. Test data must show the following elements, and the levels must not exceed the published limits for use in cooling systems.

Table 5 - Water Quality Requirements

Element Maximum Level Allowable
Calcium, Magnesium (Hardness) 170 ppm (as CaCO 3)
Chloride 40 ppm (as Cl)
Sulfate 100 ppm (as SO 4)

Fleetguard® Water-Chek™ Test Strip, Part Number CC2609, can be used to determine the quality of make-up and shop tap water. The Water-Chek™ test strip measures, Hardness, pH and Chloride levels in make up water.

Section 10 - Maintenance Records

Accurate maintenance records are important. Maintenance programs must be accompanied by accurate record-keeping practices. Records must be capable of supplying the information required for the following:

Routine cooling system maintenance records must include the following information:

Section 11 - Cleaning the Cooling System

Cooling System Cleaners

 CAUTION 

Failure to purge cleaning chemicals sufficiently can result in contamination of the new coolant during the refill process, which can lead to engine failure.

 CAUTION 

Coolants and cooling system cleaning and flushing fluids that contain 5 ppm or more of lead or 0.5 ppm of benzene are considered hazardous according to federal law in the United States of America. Disposal must be done in accordance with local, state, and federal laws.

Routine cleaning of cooling systems is not recommended. However, inadequate maintenance practices, incorrect use of coolant products, or an engine component failure (such as an oil cooler element) can lead to problems that require cleaning the cooling system. Cummins Inc. recommends the use of cleaning products when one or more of the following contaminants are found in the cooling system:

To remove oil or fuel contamination from a cooling system, a low foaming cleaner specifically designed for oil removal must be used. Fleetguard® Restore™ Heavy-Duty Cleaner is an alkaline based product that has been modified to perform as an oil and grease super cleaner. In addition, it can also effectively remove silicate gelation from a cooling system.

For cleaning poorly maintained or severely contaminated cooling systems, an acid based cleaner is recommended. Fleetguard® Restore Plus™ Heavy-Duty Cleaner is an acid based product that is excellent in removing rust, scale, solder bloom, and other corrosion contaminants from the cooling system.

Table 6 below lists various contaminants and the cleaning performance of each cleaner with respect to those contaminants. The correct cleaner must be chosen based on the type of contamination.

Table 6 - Cooling System Cleaner Application Chart

Contaminant Fleetguard® Restore™ (Alkaline) or Equivalent Product Fleetguard® Restore Plus™ (Acid) or Equivalent Product
Silicate gel Excellent Poor
Oil, grease and fuel Excellent Good
Scale Poor Excellent
Rust Poor Good
Solder bloom Poor Good

Cooling systems must be cleaned carefully when any of the above conditions are apparent. Overheating can also accompany the above conditions. If the cooling system is overheating, inspect the system to determine if it requires cleaning. It is very important to flush the cooling system of chemical cleaners completely and thoroughly at the conclusion of the cleaning process. This must be done with water and will require more than one flushing to purge the cooling system of the cleaning chemicals. See the remainder of this section for recommended cleaning procedure.

 WARNING 

When using chemical products for cleaning, follow the manufacturer's recommendations for use and disposal. Wear goggles and protective clothing to avoid personal injury.

 WARNING 

Some solvents are flammable and toxic. Read the manufacturer's instructions before using.

 CAUTION 

The use of products containing hydrochloric acid will not result in adequate system cleanup and may attack cooling system materials.

 CAUTION 

Prolonged use of any cleaner, greater than 3 hours, is not recommended.

Cleaning Procedure for Removal of Lubricating Oil and Fuel from the Engine Cooling System Using Fleetguard® Restore™ Liquid Cleaner

Prior to cleaning the cooling system, install adequate coolant system draincocks, fittings and hoses to allow the coolant to drain quickly. The system must be drained immediately upon engine shut down. Therefore, it is suggested that a tee fitting be installed in the fill line to allow the top tank/expansion tank to drain quickly. In addition, a fabricated tee connection must be installed in the lower radiator out plumbing if sufficient drain ports are not available to drain the system quickly.

  1. Operate the engine at 1200 to 1500 RPM for 30 minutes with sufficient load to open the thermostat(s) to produce flow through the radiator. Also, make certain that flow is achieved through any cab heater cores or auxiliary heat exchangers.
  2. Drain the contaminated coolant from the cooling system using available radiator, cylinder block and lower radiator hose drain ports. Flush the cooling system with hot tap water as much as possible before beginning the chemical flush procedure. Use caution when handling hot coolant and dispose of the used coolant in an approved manner.
  3. Pour 3.8 liters [1 gal] of the liquid cleaner into the radiator and finish filling the system with tap water. This mixture is satisfactory for a 12 - 14 gallon cooling system. For larger cooling systems, add 3.8 liters [1 gal] per 57 liters [15 gal] of system capacity. Do not reinstall the radiator cap. Leaving the cap off facilitates inspection of coolant flow in the radiator along with eliminating the cool-down time required for radiator cap removal.
 CAUTION 

Do not use liquid dish soap. Foaming and air lock in the cylinder head(s) can occur causing severe engine damage.

  1. Operate the engine at 1200 to 1500 RPM for 30 minutes with sufficient load to open the thermostat(s) (minimum 85°C [185°F] coolant temp) to produce flow through the radiator and/or heat exchanger(s). Operating the engine without load will prolong the cleaning process. To increase operating temperature and decrease cleaning time, disable the fan drive or cover the radiator core completely. Check for flow through the radiator. Failure to get the cooling system hot enough to fully open the thermostat(s) will leave the radiator core contaminated although the engine side will be clean. Be sure to open and/or set the heater controls in the maximum heating position. If loaded engine operation is not possible, block the thermostat(s) open to produce radiator circulation. If coolant does not become hot enough, adequate cleaning will take much longer and additional flushes can be required.
  2. Shut down the engine and drain the cleaning solution quickly by utilizing all of the available drain cocks and/or via the fabricated lower plumbing arrangement. Draining the cleaning solution quickly reduces the chances that oil residue will stick to the cooling system surfaces, which will prolong the flushing process.
  3. After the cleaning solution is drained from cooling system, fill the cooling system with plain tap water. Operate the engine for 15 minutes at 1200 to 1500 RPM while it is still hot.
  4. Drain the tap water from the cooling system. The water will contain cleaner and oil residue and must be disposed of in an approved manner.
  5. If the tap water does contain oil residue, the system must be cleaned again. Return to Step 3 above and repeat use of the cleaner until the tap water used to rinse the system has no more oil residue and no oil is observed in the radiator. It may be helpful to inspect the inside of coolant hoses and pipes for evidence of oil adhering to the surfaces.
  6. Once the cooling system is thoroughly cleaned, return the system to the original configuration and install new, fully formulated antifreeze/coolant meeting Cummins Engineering Standard 14603.
  7. If applicable, install a new coolant filter sized appropriately.

Section 12 - Coolant for Arctic Operation

There are many factors, in addition to engine coolant, that need to be considered when operating Cummins® engines in arctic climates. These are discussed in Cold Weather Operation, Bulletin 3387266, and Operation of Diesel Engines in Cold Climates, Bulletin 3379009. Operation of Diesel Engines in Cold Climates defines arctic conditions as -32°C to -54°C [-25°F to -65°F]. That bulletin recommends use of a 60 percent ethylene glycol antifreeze mixture for coolant for arctic specifications. Cold Weather Operation states that the maximum recommended mixture is 68 percent antifreeze (ethylene glycol).

To update the above recommendations on coolant for arctic operation, a review of the pertinent literature was made and reported recently. The results of the review are:

  1. Do not use propylene glycol coolant in arctic climates because of its higher viscosity compared to ethylene glycol coolants. Applications with remote radiators mounted at some distance above the engine and exposed to low temperatures can result in no coolant flow through the radiator due to high viscosity of propylene glycol coolant solutions. Use ethylene glycol coolants in the recommended range.
  2. Use ethylene glycol coolants at 65 percent glycol concentration and stay within the range of 60 to 68 percent glycol.
  3. Do not over treat the coolant with supplemental coolant additives (SCA's) beyond 0.8 units per liter [3 units per gal] due to the limited solubility of additives at these lower than normal temperatures and higher than normal glycol levels.
  4. SCA concentration must be maintained between 1.2 and 3 units per 3.8 liters [1 gal].

Section 13 - Recycled Coolants

All documents previously published on recycled coolants are now obsolete. Cummins Inc. requirements for recycled coolant are the same as for new coolant. New and recycled or reclaimed coolant must meet Cummins Engineering Standard 14603. Some recycled products; based on distillation, dual deionization, or reverse osmosis/electrodialysis of used engine coolant, are capable of meeting Cummins Engineering Standard 14603. However, glycol reclaimed from the following sources has been found to cause serious engine problems in the field:

Therefore, they would fail the field test portion of Cummins Engineering Standard 14603 and are not approved for use in Cummins® engines.

Attachment 1 - Summary of Coolant Additive Technology

Introduction

Antifreeze/coolant concentrate is made up of roughly the following components:

93 to 95 percent ethylene glycol or propylene glycol
2 to 5 percent of an additive package
1 to 3 percent water.

The glycol is present to lower the freeze point and increase the boiling point of the coolant. See Section 7 - Antifreeze, for additional benefits of glycol. The small amount of water is either contained in the additives used or is added to aid the blending of the product. This allows the additive package to better dissolve in the glycol and prevents dropout or precipitation during storage. More detail is given in the following section on the various chemicals and functions of the coolant additive package.

Coolant Additives and their Function

A fully formulated antifreeze/coolant will perform the following functions to prevent corrosion and maintain efficient heat transfer. See Section 1 - Introduction for a comparison of the functions of light-duty and heavy-duty antifreeze/coolants.

Supplemental Coolant Additives (SCAs) versus Extended Service Additives

SCA's have been around in the form of chromate based products since the mid 1950's. The chromate based SCA's were largely replaced by borate-nitrite products by the mid-1970's because of chromate's toxicity. In the mid-1980's a phosphate-molybdate based product, DCA4 was made available to improve upon the performance of the borate-nitrite products that then dominated the market. The SCA's had 3 uses.

  1. SCA was used to precharge light-duty antifreeze to make it acceptable for heavy-duty service.
  2. SCA was added at 15K to 50K mile service interval to offset both dilution and depletion. Dilution occurred as the system was refilled with light-duty coolant.
  3. SCA was used as the total additive package for treated water coolants common in warm climates and marine applications.

In the early-1990's the heavy-duty coolant market had begun to change. Most fleets no longer drained coolant at the recommended 240K mile, or 6K hour recommendation, but continued to use the same coolant until engine rebuild. Fully formulated heavy-duty coolant became more readily available and this resulted in an increase in the length of service intervals. Coolant additive replenishment was separated from servicing of the lube system and pushed out to once per year, 150K miles, or 4K hours. SCA's are not formulated for long life, extended service operation. Adding SCA to heavy-duty coolant could result in excessive levels of additives in the coolant. Over time, this excessive additive build up or high level of total dissolved solids in the coolant can cause water pump leakage as well as solder and aluminum corrosion.

The first extended service additives, Extended Service Additives or “Extenders” became available in the late-1980's and were commonplace by the mid-1990's. An antifreeze Extender is formulated to replace additive at the rate that it is consumed or depleted. This assumes that the cooling system is being topped up with a fully formulated heavy-duty coolant so that there are little or no issues with additive dilution. The composition of an Extender is based upon the depletion rate of the various components. The Extender contains a larger amount of those additives that deplete quickly and smaller amounts of those additives that are consumed at a lower rate over time. For instance, Extender contains twice the amount of nitrite and half as much phosphate as the regular SCA. This is based on the fact that nitrite depletes faster than phosphate. Extenders are formulated to maintain a proper balance of additives in the coolant over time. However, they will not establish the proper initial additive levels, therefore extenders can not be used to formulate treated water coolant.

“Organic Acid Technology (OAT)” Coolants or “Organic Acid” Coolants

For both organic acid technology (OAT) and organic acid coolant, organic acids make up the large part of the additive package. However, ethylene glycol or propylene glycol still make up 90 to 95 percent of the antifreeze as with conventional antifreeze. For this reason the heat transfer characteristics and the physical properties such as freeze and boil over protection, specific heat, etc. are very similar to other products in the market.

What is an organic acid? First a chemical is classified as organic if it contains the element carbon as part of its structure. Organic acids are just one of the many classes of organic compounds such as alcohols and carbohydrates. Common organic acids are acetic acid, better known as vinegar, and adipic acid, which is the main ingredient in baking powder. In reality it is the sodium or potassium salts of organic acids that are used as corrosion inhibitors and buffers in engine coolants. The same is true for inorganic acids such as nitric and phosphoric that are used in conventional coolants.

The use of organic acids in engine coolants goes back to the early-1950's when benzoic acid was used in hybrid type coolants in Europe. Coolants are classified as “conventional”, “hybrid”, or “organic acid technology (OAT)” based largely on how much organic acid is used in the coolant additive package.

  1. Conventional - Additive package made up predominately of inorganic type compounds
  2. Hybrid - Additive package contains a mixture of inorganic and organic acid components
  3. Organic Acid Technology (OAT) - The additive package consists of 75 to 90 percent organic acids. Also organic acid technology (OAT) coolants will generally not contain the buffers borate and phosphate or the aluminum corrosion inhibitor silicate.

DCA-4 versus Fleetcool (DCA-2)

DCA4, DCA-4 Plus & ES™ Liquid Extenders, as well as ES™ Compleat are all based on a phosphate/molybdate/nitrite additive package. These chemicals, along with other additives, provide protection to cooling system components. Many other SCAs or Extenders such as Fleetcool (DCA-2) have a borate-nitrite base and higher levels of silicate. The liner pitting protection of DCA-4 and Fleetcool (DCA-2) is equivalent, however DCA-4 provides the following advantages:

If the pitting protection performance of DCA4 and DCA2 (Fleetcool) are equivalent, then why is DCA4 a preferred chemistry?

How do SCAs/Extended Service Additives protect liners and blocks from pitting damage?

Attachment 2 - Cummins Inc., ASTM, and The Maintenance Council Specification Summary

There are three ASTM and three The Maintenance Council specifications which are pertinent.

Antifreeze/Coolant Related Specifications

  1. ASTM D6210, Standard Specification for Fully Formulated Ethylene Glycol-Base Engine Coolant for Heavy-Duty Engines
  2. Precharged Ethylene Glycol Antifreeze, The Maintenance Council RP 329, Fleet Purchasing Specification for Nitrite-Containing Ethylene Glycol-Based Coolant
  3. Precharged Propylene Glycol Antifreeze, The Maintenance Council RP 330, Fleet Purchasing Specification for Nitrite-Containing Propylene Glycol-Based Coolant

Fully formulated antifreezes meeting the above specifications provide liner-pitting protection and scale inhibition. However, low-silicate antifreezes meeting ASTM D4985 or GM 6038M do not control liner-pitting and scale formation due to the absence of nitrite and scale inhibitors.

SCA for Treated Water Coolant Related Specifications

  1. ASTM D5752, Standard Specification for Supplemental Coolant Additives (SCA's) for use in Precharging Coolants for Heavy-Duty Engines.
  2. Fully formulated SCA, The Maintenance Council RP 328, Fleet Purchasing Specification for Nitrite-Containing Supplemental Coolant Additives.

Copies of these specifications can be purchased from the following:

American Society for Testing and Materials
100 Barr Harbor Drive
West Conshohocken, PA 19428 U.S.A.
Phone: (610) 832-9500
Fax: (610) 832-9555

Technology and Maintenance Council
American Trucking Association
2200 Mill Road
Alexandria, VA 22314-5388 U.S.A.
Phone: (703) 838-1763
Fax: (703) 684-4328

Cummins Inc. Coolant Specification

Cummins Engineering Standard 14603 requires that the antifreeze/coolant meet all requirements of ASTM D6210 for ethylene glycol coolant. In addition, it must:

  1. Meet the modified ASTM D1384, the Glassware Corrosion Test. This test has stricter limits for corrosion weight loss for aluminum and solder. The solder tested shall be the standard 70/30 material and also high lead solder, which is used in many copper/brass radiators for heavy duty engine applications. Tests shall be run at both 70 percent antifreeze and 30 percent antifreeze instead of the standard 33-1/3 percent solution only.
  2. Meet the modified ASTM D2570, Simulated Service Corrosion Testing of Engine Coolants. In addition to the standard ASTM test, various rubber seal and silicon hose materials are tested for compatibility with the coolant. In addition, the standard metal corrosion weight loss limits are stricter for aluminum and solder.
  3. Meet Cummins Engineering Standard 14603, Coolant/Elastomer seal compatibility.
  4. Be field tested in Cummins® engines.

For an antifreeze/coolant to be registered as meeting Cummins Engineering Standard 14603, the antifreeze/coolant supplier must have valid test results from competent, independent testing labs as proof of meeting the above specifications.

Cummins Inc. Coolant Filter Specification

Cummins Engineering Standard 14315 is the Cummins Engineering Standard that covers coolant filter performance. The standard contains the tests required to meet Cummins Inc. performance requirements along with the performance limits for those tests. The tests required in this standard cover the following:

Media Soak
Adhesive Durability
Corrosion Flow versus Restriction
Capacity and Efficiency
Bubble
Gasket Durability
Element Collapse
Hydrostatic Pressure
Impulse Fatigue
Vibration.

Attachment 3 - Monitor C Sample Report

Monitor 'C' Coolant Analysis - CC2700
Fleetguard®, Inc.
Service Engineering
P.O. Box 6001
Cookeville, Tennessee 38502
(615) 526-9551
1-800-22-FILTER (1-800-223-4583)
Customer: Account Number:
Address: Phone: Engine:
Unit #34913504 Fluid Type: Ethylene Glycol Coolant (A/F Water SCA)
EOT E  
Date Sampled: 07/12/99
Date Tested: 08/02/99
Miles on Unit:  
Miles/Hrs. on Coolant: 129,518
Lab Sample Number: 406514
pH: 8.6
% Glycol: 73*
Freezing Point: -61°C [-78°F]
Total Dissolved Solids (%) 0.5
Liner Pitting  
-SCA (Units per Gallon): 0.6*
-Nitrite (The Maintenance Council RP 382): 248
-Molybdate 265
(The Maintenance Council RP328):  
Corrosion Products  
-Iron: 1
-Aluminum: 0
-Copper: 4
-Lead: 0
-Silicate (The Maintenance Council RP 328): 60
-Buffers  
-Phosphate (K2HPO4): 12733
-Borate (Na2B4O7): 1429
-Hardness: 0
-Chloride: 0
-Sulfate: 0
NOTE: *Chemical analysis results are PPM except where noted.

!!MONITOR C Tests are not sufficient to evaluate coolant recycling processes!!

Recommendations: SCA is underconcentrated. Glycol concentration is excessively above recommended range for antifreeze. Use 40 to 60 percent. If system is overheating, drain and flush with heavy-duty cleaner. Refill with fresh 50/50 antifreeze/water mixture. Contact Fleetguard® for proper SCA dosage. precharge system at 1.5 units SCA per gallon, and install a service filter. See "Coolant Analysis with Maintenance Recommendations" in this section.

I have personally reviewed the data and recommendations for your sample.

Diagnostician)______________________________________________________________________Date_________________

Attachment 4 - Explanation of Coolant Analysis and Maintenance Recommendations (Monitor C)

For additional information, call Fleetguard® Service Engineering at 800-223-4583 and follow the menu to get to Technical Assistance.

Attachment 5 - Benefits of Coolant Filtration

Not all heavy-duty engine OEMs require the use of coolant filters on their engines. However, it is Cummins Inc. experience that use of coolant filters reduces the total cost of engine usage. After a comprehensive review of coolant filtration in 1988, Cummins Inc. 1 concluded the following:

  1. Coolant is dirty. About 40 percent of the coolant filters taken at random from heavy-duty units in the field had a significant amount of contaminant. This agrees well with a Union Carbide study of several thousand automobile cooling systems where at least 40 percent of the coolant samples contained heavy sediment.
  2. The coolant filter is a good chemical maintenance tool. It is the most reliable way to get the needed amount of Extender/SCA into the antifreeze/coolant. This reduces the chance that the coolant will be either under or over treated. The filter serves as a visible reminder that the cooling system requires periodic maintenance.
  3. The coolant filter is a troubleshooting tool. Opening a used coolant filter and observing what has collected on the filter media is very useful in the diagnosis of engine problems.
  4. There is a direct benefit of filtering the contaminant out of coolant as it reduces wear, corrosion, cavitation-corrosion (pitting), plugging, and maintains effective heat transfer. This is of benefit to cylinder liners, cylinder liner seals, water pump seals, water pump impellers, thermostats, heat exchangers, and other cooling system components. Filtration of coolant is critical when using extended service intervals.
  5. Coolant filtration will become even more important as margin is taken out of the cooling system to reduce cost, size, and weight, while the trade cycle for vehicles in many fleets is pushed to higher mileages.
  6. Since we are trying to cool more engine with a downsized cooling system, cooling system cleanliness is an increasingly important issue. More emphasis needs to be placed on effective coolant filtration that will help maintain peak system efficiency.

In early 2002, a study was made to determine whether coolant filtration is still beneficial and necessary for Cummins® engines. This study looked at changes in coolants, engines, and coolant maintenance practices since 1988 to determine if the need for coolant filtration had increased or decreased since 1988. Also, additional technical data on coolants and filtration, not included in the 1988 study, was reviewed to determine if it supports the practice of coolant filtration. This updated study on coolant filtration concluded:

  1. Cooling system and coolant changes that have occurred since the 1988 study show an increased need for coolant filtration.
  2. Additional technical literature and data not available or not referenced in the 1988 study show improved cooling system performance due to coolant filtration.
  3. The results of the 2002 study were further updated and published in 2005 2.

It is apparent that coolant filtration continues to be an advantage to Cummins Inc. and Cummins Inc. customers and; therefore, it is recommended on linered engines.

1 Hudgens, R.D. and Hercamp, R.D., “Filtration of Coolants for Heavy Duty Engines”, SAE 881270, 1988, pp. 1-21.

2 Hudgens, R.D. and Hercamp, R.D., “An Overview of Onboard Coolant Filtration for Heavy Duty Diesel Engines”, SAE 2005-01-2014, 2005, pp. 1-14.

Appendix

Frequently Asked Questions

  1. Q: I have a C (or B) series Cummins® engine which was factory filled with Chevron Texaco, Shell Rotella Extended Life OAT Coolant. Do I need to add “Silicate Fluid for Cummins Engines only” (Silicate Fluid) to my cooling system?
    A: No.
  2. Q: I have a C (or B) series Cummins® engine which was factory filled with Chevron Texaco, Shell Rotella Extended Life OAT Coolant. I have already added Silicate Fluid to my cooling system. Do I need to drain and flush now that I find that the addition of silicates was not necessary?
    A: No.
  3. Q: I have already added Silicate Fluid to my M11 which was factory filled with Chevron Texaco, Shell Rotella Extended Life OAT Coolant. Do I need to add more Silicate Fluid?
    A: No.
  4. Q: I have an ISX engine which was factory filled with Chevron Texaco, Shell Rotella Extended Life OAT Coolant and a lubricating oil filter head gasket is leaking. Can I use Chevron Texaco, Shell Rotella Extended Life coolant after I have the gasket replaced?
    A: Yes. Just drain and dispose of the used coolant in accordance with local environmental regulations. Replace the lubricating oil filter head housing gasket and refill the cooling system with Chevron Texaco, Shell Rotella Extended Life OAT Coolant 50/50. Add 0.24 liter [8 ounces] bottle of Silicate Fluid per every 45 liters [12 gallons] of total cooling system volume. Circulate the engine coolant for 15 to 20 minutes, or until the thermostat opens. Check the freeze point and adjust to -37°C [-34°F].
  5. Q: I have an ISX which was factory filled with Chevron Texaco, Shell Rotella Extended Life OAT Coolant. I have already added Silicate Fluid to the cooling system. My coolant inadvertently became contaminated and I plan to flush and refill with new Chevron Texaco, Shell Rotella Extended Life OAT Coolant. Do I need to treat again with Silicate Fluid?
    A: No. If the original gaskets remained in place, adding Silicate Fluid again will not be required.
  6. Q: I have heard that using Chevron Texaco or Shell Rotella Extended Life OAT Coolant in Cummins® engines was responsible for N14 rocker housing gasket failures. Is this true?
    A: A joint team of Cummins® and Chevron Texaco experts determined that a unique combination of circumstances needed to be present in order for the rocker housing gasket leakage to occur.
  7. Q: I have heard that the use of Chevron Texaco or Shell Rotella Extended Life OAT Coolant in Cummins® engines can lead to catastrophic failures, including oil solidification (gelation).
    A: The use of Chevron Texaco or Shell Rotella Extended Life OAT Coolant will not necessarily lead to catastrophic failure or oil solification in Cummins® engines. Oil and coolant must never be mixed regardless of engine make or coolant formulation.

    The presence of coolant in the engine oil represents a serious situation that must be remedied immediately. Testing of the oil is the best way to determine if coolant has mixed with the engine oil.

    Intrusion of any coolant; be it conventional, fully formulated, extended service hybrid or OAT/ethylhexanoic acid based, into crankcase oil can lead to sludge, solidification and potential catastrophic engine failure.
  8. Q: What has changed? It is now OK to use the coolant, but before it was not?
    A: Intense investigations proved that more than one factor caused the failure of a certain percentage of rocker housing gaskets in Cummins® N14 engines. The one time addition of the Silicate Fluid is a preventive maintenance step recommended by Chevron Texaco and Cummins Inc. to help prevent seal degradation.
  9. Q: How does one application of the silicate additive provide the required protection for engine such as the N14?
    A: The effectiveness of silicates has been demonstrated in laboratory, dyno and field studies, and has been shown to be effective in extending the life of silicon seals in Cummins® engines at the recommended dosage level. Early introduction of the silicate is believed to create a protective barrier at the surface of the seal that does not allow free contact of coolant and the seal surface.
  10. Q: Can Chevron Texaco, Shell Rotella Extended Life OAT Coolants be used with Cummins® High-Horsepower industrial engines such as the QSK/KV, the V28 or the QSK78 series engines?
    A: Yes, Chevron Texaco, Shell Rotella Extended Life OAT Coolants, which do not meet the elastomer compatibility section of CES 14603, are acceptable for extended service interval use in High-Horsepower industrial engines, assuming the initial coolant fill requirements were met by the original equipment manufacturer (OEM). Contact a Cummins Authorized Repair Facility to request AEB 90.47.
  11. Q: My N14, ISM or ISX engine, which has Chevron Texaco or Shell Rotella Extended Life OAT Coolants + Silicates as coolant, is being repaired. Assuming the coolant is not contaminated and in good condition, can it be reused?
    A: The coolant can be reused if the repair procedure does not require replacement of any coolant system gaskets. If any coolant system gaskets listed above are replaced, the coolant must be replaced with new 50/50 TELC and add a 0.24 liter [8 ounce] bottle of Silicate Fluid per every 45 liters [12 gallons] of total cooling system volume.
  12. Q: How can I get more information on the maintenance requirements of Chevron Texaco, Shell Rotella Extended Life OAT Coolants, and Chevron Texaco, Shell Rotella Extended Life OAT Coolants + Silicates? What tests are required to be sure that the coolant's condition and operation meet the engine's needs?
    A: Call 1-800-782-7852 and choose the technical information option. If you would like to test this OAT coolant for inhibitor level at your site then you can use the Extended Life Coolant Test Strip (ELCTS). These test kits can be ordered from Analyst Inc. at 1-800-336-3657. It must be noted that it is very important to maintain freeze protection of the coolant. The optimum freeze protection is -37°C [-34°F] even if the engine is located in warmer weather climates.
  13. Q: If a N14 rocker lever housing gasket is being replaced, will silicates need to be added regardless of mileage or time since silicates were originally introduced to that engine?
    A: Yes. It is recommended that a 0.24 liter [8 ounces] bottle of Silicate Fluid per every 45 liters [12 gallons] of total cooling system volume be added to the coolant IF replaced with Chevron Texaco or Shell Rotella Extended Life OAT Coolants.
  14. Q: Can excessive amounts of Silicate Fluid in the coolant induce issues that could impact engine performance?
    If over-treatment is suspected, draining the system, flushing, replacing new coolant and adding a 0.24 liter [8 ounces] bottle of Silicate Fluid per every 45 liters [12 gallons] of total cooling system volume is the recommended action.


Last Modified:  13-Dec-2005